• Find RepFree Estimate
    2-gallon pail
    10.3 oz tube

    Terminator 622™

    Built for tough repairs, Terminator 622 is a 100% solids, moisture-cure sealant and adhesive with exceptional elasticity and adhesion. Its advanced formula bonds to most surfaces—even in wet conditions—delivering waterproof, UV-stable protection for lasting performance.

    • Self-leveling formulation for seams, fasteners, flashings, ridge caps, and penetrations
    • One-component, moisture-curing multi-purpose sealant and adhesive
    • Designed for applications requiring high elasticity and strong adhesion
    • Can be applied in cold-weather conditions, including below freezing temperatures
    • Maintains performance in temperatures as low as -40°F
    • Bonds to damp surfaces and resists washout during cure
    • Cures to form a durable, flexible, waterproof seal
    • Low-odor formulation with minimal shrinkage
    • Non-staining and mildew-resistant performance
    • Excellent UV resistance for long-term durability
    • VOC-compliant formulation
    Solids by Volume
    100%
    Elongation
    500%
    Tensile Strength
    200 psi
    Flash Point
    N/A
    Hardness
    25 (5 day ambient cure)
    Dry Time
    2–12 hours
    Service Temperature
    -40° to 200°F
    Low Temperature Flex
    -20°F
    Slump
    Some self-leveling
    • Modified bitumen
    • Metal
    • TPO
    • PVC
    • EPDM
    • Spray polyurethane foam
    • Smooth built-up roofing
    • Concrete
    • Surface Preparation

      Ensure the surface is clean, dry, and free of debris, grease, mildew, and loose material before application. If necessary, pressure wash (2,500–3,500 psi) to remove contaminants.

       

      Inspect and repair damaged areas before applying the product. Depending on the substrate’s age and condition, a primer may be required.

    • Mixing/Thinning

      Mix thoroughly with a drill mixer for ~3 minutes to ensure uniform consistency. If thinning is necessary, consult Technical Services for specific recommendations. Avoid excessive air entrapment during mixing.

    • Application Methods

      Depending on project requirements, apply using a trowel, putty knife, stiff-bristled brush, or extrusion equipment.

    • Coverage Rate

      Coverage varies depending on substrate and application thickness. Refer to application guidelines for specific rates.

    • Cure Time

      Forms a surface skin within 2–4 hours under normal conditions. Full cure occurs in 7–10 days, depending on temperature and humidity.

    • Limitations/Precautions

      Do not apply if surface temperature is below 40°F, as it may hinder curing. In cold weather, store indoors until use to maintain consistency.

       

      High humidity speeds curing; low humidity slows it. Avoid application if rain is imminent, as moisture can interfere with adhesion.

    • Storage/Handling

      Store in a cool, dry place, away from sunlight and heat. Keep containers sealed to prevent moisture exposure and premature curing.

       

      While freezing rarely causes damage, extreme temperature fluctuations can affect product consistency. Store in controlled conditions to prevent freezing.

    • Cleanup/Disposal

      Clean tools and equipment immediately after use with an appropriate solvent. Dried material may require mechanical removal.

       

      Do not dispose of liquid material in drains or waterways. Follow local, state, and federal regulations for proper disposal of unused product and empty containers.

    Contact Sales